Pensky martin flash point tester hfp 380 pdf

Manual flash point analyzers pensky martens, tag, abel and cleveland open cup coc hfp 384 abel hfp 382 tag hfp 380 pensky martens designed to provide years of accurate and reliable flash point results, herzogs top quality hfp 38x series closed and open cup flash point. Pensky martens, tag, abel and cleveland open cup coc. Martens and was based on the original tester by mr. The flash point is the lowest temperature at which a liquid sample vaporizes to form an ignitable mixture with air. Fp 360 series flash point analyzers save time, money and bench space through efficient, automated operation, accurate, repeatable results, and a compact design. K16225 stirrer motor, 115230v 5060hz slow speed gear motor rotates stirrer of pensky martens tester at 105rpm for procedure a and at 250rpm for procedure b. Pacs herzog optiflash is the new benchmark in flash point analysis, fully designed to. Berthold pensky developed the first closedcup flash point tester and set a milestone for the production of flash point testers based on quality and precision.

In addition to standard test methods, the hfp 339 may be programmed with userdefined test electric or gas ignition protocols and test for samples with an unknown flash. Pensky martens is a closedcup test method, meaning that it aims to simulate a liquid spill in a closed environment. Flash point testers list of new and used for sale labequip. Astm d92, iso 2592, jis k22654, ip 36, aashto t48, ftm 7911103, gost 4333 the best flash point tester. The automated pensky martens flash point analyzer represents a perfect union of nextgeneration technology with traditional robust quality. A wide variety of flash point tester options are available to you, such as usage, power. Automated pensky martens flash point analyzer optiflash. Pensky martens flash point apparatus with voltage varic control oil test jet. Flashpoint with closed cup penskymartens method pma. Consult pacs entire hfp 360 automatic closed cup penskymartens flash point analyzer catalogue on directindustry. Unlimited number of user programs including a quick test that safely tests from ambient, puts the flash point. Pma 5 comes completely ready for testing with automatic test routines, user. Pensky martens flash point is automatically determined in strict compliance with the appropriate test method. The pensky martens test is a closedcup method as opposed to the cleveland opencup method.

Anumber in parentheses indicates the year of last reapproval. Manual pensky martens closed cup flash point tester k162xx this certificate verifies that part number k162xx, manual pensky martens closed cup flash point tester, was manufactured in conformance. Standard test methods for flash point by pensky martens closed cup tester1 this standard is issued under the. Flash point models hfp 384 abel hfp 386 cleveland open cup methods iso 736 ip 170 astm d92. Qualtech products industry professional automatic flash point tester is a precision penskymartens closedcup flashpoint test instrument to determine the flashpoint of volatile samples. K16225 stirrer motor, 115230v 5060hz slow speed gear motor rotates stirrer of penskymartens tester at 105rpm for procedure a and at 250rpm for procedure b. Pensky martens tag abel choice of configurations semiautomatic or manual operation 230 or 115 vac gas ignition optional bath cooling accuracyenhancing flash alert available semiautomatic and manual flash point testers hfp 380 series d esigned to provide years of accurate and reliable flash point results, herzogs top. John morris group service, support and supply some of the worlds finest technical solutions to industries such as research, mining, petroleum, educational institutes, manufacturers and environmental testing.

Penskymartens flash point tester procedure adam flink. Automatic pensky martens closed cup flash point analyzer 110240v 5060hz koehler k7 for international destinations automatic tag closed cup flash point tester 115v. Pensky martin apparatus chemistry full description graph and complete analysis in hindi duration. Buy koehler k16270 pensky martens closedcup flash tester, 220 vac50 hz and more from our comprehensive selection of koehler manual flash point testers covid19 update. Pensky martens, tag, abel and cleveland open cup coc hfp. Tanaka automatic petroleum tester quintech scientific. A number in parentheses indicates the year of last reapproval. Berthold pensky developed the first closed cup flash point tester and set a milestone for the production of flash point testers based on quality and precision. To support you, coleparmer is open for business and shipping product daily. Flash point testers clarkson laboratory and supply inc.

Pensky martens flash point apparatus with voltage variac, electronic digital temperature indicator and constant speed stirring device oil test jet. Qualtech products industry professional automatic flash point tester is a precision pensky martens closedcup flash point test instrument to determine the flash point of volatile samples. According to astm d9318, pensky martens test procedures can determine the flash point. There are two basic methods for determining the flash point of a volatile liquid. Flash point tester pensky marten type it consist of the following components. Basics of penskymartens closedcup flash point testing anton. Test method for flash point determinations of fuels, lubricating oils, liquids containing suspended solids and liquids that tend to form a surface film during testing. Procedures are preprogrammed for homogeneous petroleum liquids, residual fuel oils and other nonhomogeneous liquid and biodiesel.

Pensky martens flash point apparatus with voltage varic with geared electric motor stirrer 120 r. Koehler k7 penskymartens closedcup flash point tester. Stirrer motor, 115v 60hz 1 slow speed gear motor rotates stirrer of. Hfp series automatic flash point analyzers interchangeable test modules enable you to perform pensky martens, tag, and abel flash point tests using a single base instrument. Manual flash point analyzers pensky martens, tag, abel and cleveland open cup coc hfp 384 abel hfp 382 tag hfp 380 pensky martens designed to. The system software runs on an integrated processor pc running the latest windows operating system. Koehler instrument flash point cup for penskymartens closed.

Koehler instrument flash point cup for pensky martens closed tester flash point test cup spectrophotometers, refractometers and benchtop instruments. Hfp series automatic flash point analyzers are designed to simplify the testing of hydrocarbon samples using the penskymartens or other closed cup test. Over 65,000 results of data can be stored on the local hard drive. Penskymartens flash point tester fpm ducom instruments. Includes adjustable support bracket and mounting rod.

The united states environmental protection agency epa has also published method 1010a. Through partnerships, cannon is proud to offer several types of automated flash point testers to suit a variety of testing needs. Hfp38x pac pdf catalogs technical documentation brochure. Proven, reliable an elevated flash point, the hfp 339 has the operation hfp 339 t he hfp 339 flash point analyzer is the latest generation of herzog products well known for proven reliability, superior design and quality.

Flash point apparatus pensky martin flash point apparatus. Pensky martens flash point tester at rs 1piece pensky. Jun 16, 2010 procedure of using the pensky martens flash point tester at btc process technology lab. Makes penskymartens, tag, and abel flash point testing. Penskymartens closedcup flash point testerlab test. Order qty pensky martens closed cup flash tester 1 k16203. Pma 5 comes completely ready for testing with automatic test routines, userdefinable.

Professional automatic closedcup flash point tester. Pensky martens closed cup flash point tester apm7 model apm7 is the latest version of the automated pensky martens closed cuppmcc flash point tester from tanaka. Temperature measurement intelligent pt 100 probe with built in calibration, 10 calibration points. In addition, the hfp 380 is available with a cooling fan. Pensky martens flash point is automatically determined in strict compliance with the appropriate test. Its development in 1870 was for flash points well above 100 c to test lubricating oils and other similar. Test methods for flash point by pensky martens closed cup tester, part of test methods for evaluating solid waste, physicalchemical methods, which references the astm standard series d93. May 18, 2015 with an integrated fire extinguisher, the pensky martens flash point tester pma 5 highly improves user safety. Test methods astm d93, ip 34, din 51758, en 2719, gost r en iso 2719 description designed to provide years of. Pensky martens flash point is automatically simple, userfriendly determined in strict compliance with the appropriate operation test method. Through partnerships, cannon is proud to offer several types of automated flash point. A brass test cup is filled with a test specimen and closed with a lid, through which an.

Flashpoint with closed cup penskymartens method pma 4. Optiflash pensky martens determines the flash point of petroleum products, biodiesels, solvents, fluxed bitumen, food, and beverages. Automatic application of test flame optional cooling device advantages. Most of our asphalt test apparatus are astm compliant with standard asphalt evaluating protocols, for use in road paving quality control qc and research labs. Integrated dual fan system directly cools the test cup and the environment around test cup. Pensky martin apparatus chemistry full description graph and complete analysis in hindi. All units include a rugged electric heater with ultraprecise manual control, mercury thermometer, and visual flash point detection. In addition to standard test methods, the hfp 339 may be programmed with userdefined test electric or gas ignition protocols and test for samples with an unknown flash safety and fire detection systems. Automated pensky martens flash point analyzer optiflash flash point measuring range 30oc to 400oc heating system heater band for uniform heating of the heater block, test method or userde. Penskymartens flash point tester rigana south africa. The apm8fc is an automated pensky martens closed cup flash point tester with builtin fire containment. Koehler instrument flash point cup for penskymartens.

Astm d93 standard test methods for flash point by pensky. Pensky martens tag abel choice of configurations semiautomatic or manual operation 230 or 115 vac gas ignition optional bath cooling accuracyenhancing flash alert available semiautomatic and manual flash point testers hfp 380 series d esigned to provide years of accurate and reliable flash point. Product description the koehler k7 automatic pensky martens closed cup flash point analyzer is for flash point determination of biodiesel, distillate fuels, new lubricating oils, residual fuel oils, cutback residua, used lubricating oils, mixtures of petroleum liquids with solids, petroleum liquids that tend to form a surface film during testing. Standard test methods for flash point by penskymartens closed cup tester1 this standard is issued under the. Manual pensky martens closed cup flash point tester k162xx this certificate verifies that part number k162xx, manual pensky martens closed cup flash point tester, was manufactured in conformance with the applicable standards set forth in this certification. Astm d93 19 standard test methods for flash point by pensky. Pensky martens closed cup flash point tester wo stirrer motor 115v koehler k16203 pensky martens closed cup flash point tester wo.

Qualtech products industry professional automatic flash point tester is a precision penskymartens closedcup flash point test instrument to determine the flash point of volatile samples. This will be detected and signaled, preventing an accident or damage. Test methods astm d93, en iso 2719, ip 34, iso 2719, jis k2265. Hfp 380 without cooling van 038009 0380 hfp 380 with coolingvan 038010 038014 hfp 382 038210 038214 flash point models hfp 384 abel hfp 386 cleveland open cup methods iso 736 ip 170 astm d92 iso 2592 ip 36 din en 22592 heater electric with manual control electric with manual control. The fpm provides accurate and secure flash point testing for users seeking to characterize the volatility and flammability of biodiesel fuels, lubricating oils and petroleum products. Flash point models hfp 380 pensky martens hfp 382 tag methods astm d93 a, b, c iso 2719 a, b, c en 22719 a, b, c. Automated closed cup flash point analyzers hfp 36x series. There are substances which do not have a flash point in a closed cup. Berthold pensky developed the first closedcup flash point tester and set a milestone for the production of flash point. The automatic pensky martens closedcup tester measures the flash point at the lowest temperature at which the application of an ignition source causes the vapors of a sample to ignite. With an integrated fire extinguisher, the pensky martens flash point tester pma 5 highly improves user safety. Herzog automatic flash point tester english to serbo.

Closed cup flash point analyzers optimus instruments. For flash point determinations of liquids with a viscosity of below 5. Conforms to astm d 3243, d 3278 and d 3828, flash point by setaflash tester. Unit has digital temperature circuitry and temperature. Note 1flash point determination as above 250c can be performed, however, the precisions have not been determined above this temperature. Berthold pensky developed the first closed cup flash point tester and set a milestone for the production of flash point. Hfp series automatic flash point analyzersare designed to simplify the testing of hydrocarbon samples using the penskymartens or other closed cup test. Fp 360 series flash point analyzers save time, money and bench space through efficient. About 85% of these are testing equipment, 0% are gas analyzers, and 0% are moisture meters.

Astm d93, iso 2719, ip 34 cleveland opencup flash and fire point tester. Hcp 852 automated pour point and cloud point analyzer. Standard test methods for flash point by penskymartens. Pensky martens flash point apparatus with voltage variac, electronic digital temperature indicator and constant speed stirring device oil test. Designed to provide years of accurate and reliable flash point results, herzogs top quality hfp 380 utilizes the pensky martens closed cup method.

For flash point determinations of fuels, lubricating oils, liquids containing suspended solids and liquids that tend to form a surface film during testing. When this seventh generation model was designed after 35 years of delivering the automated flash point. Procedure of using the pensky martens flash point tester at btc process technology lab. Fire point is the temperature at which the test flame causes the sample to ignite and remain burning for. According to astm d9318, pensky martens test procedures can determine the flash point of petroleum products in the 40c.